基于冷却循环水输送系数的冲压车间用冷却循环水泵能效分析
|
英文标题:Energy efficiency analysis on cooling circulating water pump in stamping workshop based on cooling circulating water transfer factor |
作者:安锐 谢小琛 |
单位:一汽-大众汽车有限公司 |
关键词:冷却循环水输送系数(WTF) 冷却循环水泵 恒压变频 压力设定值 能效 冲压车间 |
分类号:TG305 |
出版年,卷(期):页码:2021,46(2):185-189 |
摘要:
|
采用冷却循环水输送系数(WTF)来分析冲压车间配套使用的冷却循环水泵的能效。首先,给出了冷却循环水输送系数的计算方法;然后,根据GB/T 19781—2007中空调用冷却循环水泵的WTF限值,折合出冲压用冷却循环水泵的WTF限值,分析了影响冷却循环水泵WTF的因素。根据一汽-大众5个基地的冲压用冷却循环水泵实测数据,计算得到WTF瞬时值,并与其折合的WTF限值进行比较,从水泵控制、运行维护、末端用冷设备控制几个角度,分析了目前WTF值较低的原因,得到了使用恒压变频控制、根据不同季节调整压力设定值、按规定压差清洗过滤罐、有效控制末端电磁阀等措施有利于提高冷却循环水输送系数WTF的结论。
|
The energy efficiency of cooling circulating water pump used in stamping workshop was analyzed by cooling circulating water transfer factor(WTF). Firstly, the calculation method of WTF was given, and then the factors affecting WTF of cooling circulating water pump were analyzed based on WTF limit values of cooling circulating water pump for air conditioning in GB/T 19781—2007 to convert that for stamping. Furthermore, according to the measured data of cooling circulation water pump for stamping in five car plants in FAW-VW, the instantaneous value of WTF was calculated and compared with its equivalent WTF limit value, and the reasons for the current low WTF value were analyzed from the perspectives of water pump control, operation and maintenance, and terminal cooling equipment control. The results show that using the measures of constant pressure and frequency conversion control, adjusting the pressure setting value according to different seasons, cleaning the filter tank based on the specified pressure difference and effectively controlling the terminal solenoid valve are beneficial to improve WTF.
|
基金项目:
|
|
作者简介:
|
安锐(1990-),男,硕士,工程师,E-mail:anrui135@163.com
|
参考文献:
|
[1]田文彪,魏明,尹娟,等. 汽车制造企业能耗分析及节能新技术[J]. 节能,2017,26(11):21-23. Tian W B, Wei M, Yin J, et al. Analysis of energy consumption in automotive manufacture industry and some new methods for energy conservation[J]. Energy Conversation, 2017, 26(11): 21-23. [2]赵振家,张鹏,赵明楠,等. 汽车制造过程的能耗及碳排放分析[J]. 中国人口·资源环境,2017, 27(5):186-190. Zhao Z J, Zhang P, Zhao M N, et al. Analysis of energy consumption and carbon emission for automobile manufacturing process[J].China Population, Resource and Environment, 2017,27(5): 186-190. [3]杨俊,苏恒,陈中祥. 液压机批量成形控制策略 [J]. 锻压技术,2020,45(1):151-155. Yang J,Su H,Chen Z X. Batch forming control strategy of hydraulic press [J]. Forging & Stamping Technology,2020,45(1): 151-155. [4]徐济宣,马辉. 重型液压机执行器自适应滑模容错控制 [J]. 锻压技术,2020,45(4):140-146. Xu J X,Ma H. Adaptive sliding mode fault-tolerant control of actuator for heavy-duty hydraulic press [J]. Forging & Stamping Technology,2020,45(4): 140-146. [5]王庆阳,高梦迪,李磊,等. 冲压成形节能优化方法[J]. 锻压技术,2019,44(6):134-144. Wang Q Y, Gao M D, Li L, et al. Energy-saving optimization method of stamping [J]. Forging & Stamping Technology, 2019, 44(6):134-144. [6]高梦迪. 冲压成形加工过程低碳节能优化方法研究[D].合肥:合肥工业大学,2017. Gao M D. Research on Low Carbon and Energy Saving Optimization Method for Stamping Forming Process[D]. Hefei: Hefei University of Technology, 2017. [7]朱明亮,张中琳,丁宵月,等. 基于快速换模技术的压机设备的利用率改善及快速换模系统的电气设计 [J]. 锻压技术,2020,45(11):168-176. Zhu M L,Zhang Z L,Ding X Y,et al. Improvement on utilization of press equipment based on rapid mold change technology and electrical design of rapid mold change system [J]. Forging & Stamping Technology,2020,45(11):168-176. [8]周春生,刘志峰,黄海鸿,等. 基于遗传算法的冲压车间节能调度优化研究[J]. 制造业自动化,2018, 40(5):58-64. Zhou C S, Liu Z F, Huang H H, et al. Energy-saving scheduling optimization study based on genetic algorithm in pressing job-shop[J]. Manufacturing Automation, 2018,40(5):58-64. [9]徐刚. 大型汽车冲压生产线技术与装备现状与发展[J].锻压装备与制造技术,2016,51(6):7-13. Xu G. The status and development of punching line technology and equipment for heavy truck[J]. China Metalforming Equipment & Manufacturing Technology, 2016,51(6):7-13. [10]刘阿祺, 王鑫, 魏庆芃. 冷却水输送系数的获取方法及其在节能诊断中的应用[A]. 全国暖通空调制冷学术年会[C]. 重庆, 2008. Liu A Q, Wang X, Wei Q P. Obtain water transfer factor and its use in energy diagnose[A]. HVDC Academic Annual Conference[C]. Chongqing, 2008. [11]周严,魏庆芃,胡新语,等. 空气源热泵系统在胶东地区使用的使用效果实测[J]. 暖通空调,2017,47(10):142-148. Zhou Y, Wei Q P, Hu X Y, et al. Field measure and analysis on operational performance of air-source heat pump systems in Jiaodong area[J]. Journal of HV&AC, 2017, 47(10):142-148. [12]GB/T 17981—2007,空气调节系统经济运行[S]. GB/T 17981—2007,Air conditioner system economic operation[S].
|
服务与反馈:
|
【文章下载】【加入收藏】
|
|
|